JIRS FL-8870 — Electromagnetic flow meter

JIRS FL-8870 — Electromagnetic flow meter — Flow measurement. item: Specification; model: FL‑8870 E‑mag C Type; nominal diameter: DN3 ~ DN3000.

JIRS FL-8870 — Electromagnetic flow meter

Price on quotation

Confirm availability

Delivery confirmed for your order.

Item
Specification
Model
FL‑8870 E‑mag C Type
Nominal Diameter
DN3 ~ DN3000
Nominal Pressure
0.6 MPa, 1.0 MPa, 1.6 MPa, 4.0 MPa, 6.3 MPa
Measuring Accuracy
DN15‑DN600: ±0.3% reading(≥1m/s); DN3‑DN10 / DN700‑DN3000: ±0.5% reading(≥0.8m/s)
Medium Conductivity
≥5 μS/cm
Max Flow Velocity
15 m/s
Lining Material
PTFE(F4), F46, PFA, Poly neoprene, Polyurethane
Electrode Material
SS316L, Hastelloy B, Hastelloy C, Titanium, Tantalum, Platinum‑iridium alloy, Tungsten‑carbide coated stainless steel
Converter Type
Round integrated / Square integrated / Square separated; push‑button / magnetic button
Power Supply
AC 85‑265 V 45‑400 Hz; DC 19‑40 V
Power Consumption
<20 VA (including sensor)
Output Signal
4‑20 mA analog; 0‑5 KHz pulse; dual alarm relay; RS232, RS485, HART, Profibus‑DP
Environment Temp
Converter: ‑25 ℃ ~ +60 ℃; Sensor:‑40 ℃ ~ +60 ℃
Medium Temperature
Depends on lining material (80‑150 ℃)
Protection Grade
IP65 / IP67 / IP68
Explosion‑proof Grade
Exdibmb Ⅱ CT6 Gb, ExdibmbIIB+H2T6 Gb, ExibmbIIB+H2T6 Gb
Separated Cable
STT3200 special cable, max distance 100 m
Standard Flange
GB/T9119, GB/T9115